Product map - Detector


AirFlow sensor 5101

Door contact MK4

Gas Leak Detector

Motion PIR Detector

Optical Smoke Detector FDR26

Power Detector

PowerEgg2

Sensor WLD Relay 1W-UNI

Vibration detector SS14

Vibration detector SS14-v2

Measurement

Measurement Flow
Range: 0–1 switch
Accuracy: 1
Resolution: 1.00
Technology: Semiconductor
Switch
Range: 0–1 switch
Resolution: 0.00
Range: 0–1 switch
Resolution: 0.00
Motion Smoke
Range: 0–1 switch
Accuracy: 1
Resolution: 1.00
Technology: Semiconductor
Voltage Voltage Water detection
Technology: Resistor
Vibration Vibration
Number of values provided 1 1 1 1 1 1 1 1 1 1
Inputs
Counters: NO
Inputs type: Wet Contact
Counters: NO

Inputs type: Dry Contact
Counters: NO
Inputs type: Water Leak Detection zone
Quantity: 1
Counters: NO
Outputs
Output type: Relays standard
Load voltage: 230V / 3000mA
Output type: Relays standard
Quantity: 1
Load voltage: 50V / 500mA
Output type: Relays standard
Quantity: 1
Load voltage: 230V / 5000mA
Output type: Open colectors
Quantity: 1
Load voltage: 50V / 50mA
Output type: Relays standard
Quantity: 1
Load voltage: 50V / 500mA
Output type: Open colectors
Quantity: 1
Load voltage: 50V / 130mA
Output type: Relays 110/230V
Load voltage: 230V / 8000mA

Output type: Relays standard
Quantity: 1
Load voltage: 120V AC/60V DC / 1000mA
Output type: Relays standard
Load voltage: 120V AC/60V DC / 1000mA
Output type: Open colectors
Load voltage: 120V AC/60V DC / 40mA
Output type: Open colectors
Load voltage: 30V DC / 100mA
Cable length 2 meter 2 meter None None None None None 3 meter None None
Galvanic isolation 1 1 1 0 1 1 1 0 1 1
Units Converter NO NO NO NO NO NO NO YES NO NO
Calibrated Points None None None None None None None None None None

Power and dimensions

Power supply
Power supply: 24V / 40mA
Connector: Wire
Power supply: 12V / 100mA
Connector: Terminal Block
Power supply: 12V / 35mA
Connector: Terminal Block
Power supply: 12V / 55mA
Connector: Terminal Block
Power supply: 230V / 3mA
Power supply: 230V / 13mA
Connector: IEC-320 C14
Power supply: 9-15V / 20mA
Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm)

Power supply: 9-15V / 20mA
Connector: Terminal Block

Power supply: 5V / 40mA
Connector: RJ-11 (from 1-Wire)
Power supply: 12V / 18mA
Connector: Terminal Block
Power supply: 12V / 20mA
Connector: Terminal Block
Operating environment -10°C ÷ 50°C / 0%RH ÷ 90%RH -20°C ÷ 80°C / 0%RH ÷ 100%RH -10°C ÷ 40°C / 25%RH ÷ 75%RH -10°C ÷ 40°C / 20%RH ÷ 80%RH 0°C ÷ 70°C / 0%RH ÷ 95%RH -30°C ÷ 60°C / 0%RH ÷ 100%RH -20°C ÷ 80°C / 0%RH ÷ 80%RH -30°C ÷ 85°C / 0%RH ÷ 100%RH -20°C ÷ 50°C / 0%RH ÷ 100%RH -20°C ÷ 50°C / 0%RH ÷ 95%RH
Storage environment -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -20°C ÷ 50°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -20°C ÷ 50°C / 0%RH ÷ 95%RH
Depth 10mm 39mm 53mm 50mm 41mm 34mm 21mm 21mm
Dimensions 24mm / 141mm / / 157g 12mm / 51mm / 10mm / 50g 100mm / 74mm / 39mm / 112g 61mm / 110mm / 53mm / 77g 100mm / 45mm / / 185g 60mm / 60mm / 50mm / 80g 58mm / 124mm / 41mm / 146g 79mm / 68mm / 34mm / 122g 37mm / 78mm / 21mm / 33g

Type

Environment Industrial, IT Industrial, SoHo, IT Industrial, SoHo, IT SoHo, IT SoHo, IT Industrial, SoHo, IT Industrial, SoHo, IT Industrial, IT Industrial, SoHo Industrial, SoHo
Installation Rack, Wall Table, Wall Wall Wall Rack, Table, Wall Table, Wall Wall
IP Rating IP67 IP40 IP33 IP33 IP40 IP23 IP33 IP23 IP30
Connectors Terminal Block Terminal Block Terminal Block Terminal Block Terminal Block Terminal Block Terminal Block RJ11, Terminal Block Terminal Block Terminal Block
Design Rod, Room Dry contact Dry contact Mural Mural Mural Mural Mural Mural